-40%

BAOSHISHAN Zahn Cup Viscosity Cup #1 to #5 Dip Type 44ml Stainless Steel Visc...

$ 117.44

Availability: 20 in stock
  • EAN: Does not apply
  • Condition: New
  • Manufacturer Part Number: CJH-ZQ-855
  • Item must be returned within: 30 Days
  • Return shipping will be paid by: Seller
  • All returns accepted: Returns Accepted
  • UPC: Does not apply
  • Brand: BAOSHISHAN
  • MPN: CJH-ZQ-855
  • Refund will be given as: Money Back

    Description

    Brand New BAOSHISHAN Zahn Cup Viscosity Cup #1 to #5 Dip Type 44ml Stainless Steel Viscometer Flow Cup for Paint Finishes Oil
    Manufacturer model:
    CJH-ZQ-855
    Volume of cup: 44ml, Efflux time(sec): 20-80sec
    All 5 models, test viscosity from 10-1800 centistokes (cSt)
    Meets ASTM D4212 standard quickly measure the viscosity of liquids such as Paint,Ink,Varnishes,Syrup and Oil.
    The Stainless Steel Cups are molded precisely and the orifices are precision drilled using high-speed CNC drilling.
    Boshi Electronic Instrument is a professional seller of paint testing instruments. We have so many instruments can be used to measure the viscosity, fineness, abrasion resistance, density and adhesion of paint and ink or other non-Newtonian liquids.
    Description
    Product Description
    Zahn Immersion Viscosity Cup
    This is a Zahn type Cup Viscometer which are used to measure the flow behavior of liquids such as paints and is in very nice condition.Applicable to the construction site to
    quickly measure the viscosity of the paint
    to be sprayed; more widely used in electronic products, plastic coatings industry. The cup and Iwata spray gun together become essential plant construction tools.
    Fast determination
    of fluid viscosity such as ink, paint and dye.
    According to
    ASTM D 4212 Standards
    (Standard Test Method for Viscosity Cup Immersion).
    Cup 1# ~ 5 #
    available for different materials
    Mainly applied to
    maintain the stability of the viscosity
    of the product in the process of use, so that the viscosity is always maintained at the set range to protect the color of the product effect.
    Zahn Cup Operation Method & Maintenance
    1.Clean before Testing
    Choose the appropriate cup size
    before testing, so that the time of outflow can be controlled between 20 and 80 seconds. Wipe it clean with the appropriate solvent and dry it before using.
    2. Liquid Temperature Control
    Adjust the temperature
    of the filtered sample and the outlet cup to 25℃ or a specific temperature, keep the temperature constant, and immerse the cup in the container for 1-5 minutes to achieve a thermal balance.
    3. Test and Time
    Lift the cup vertically from the sample, and the movement needs to be fast and steady. Start the timer when the the upper end of the cup leaves the liquid level and.
    Keep the cup vertical
    when the liquid flows out and the distance from the liquid surface should not exceed 150mm.
    4. Viscosity Value Conversion
    Stop timing when the first breakpoint occurs. Repeat the test 2-3 times. Take the average time to reduce the error and the difference between the two measurements should be less than 5% of the average. Then
    use the formula v=k (t-c)
    to convert the viscosity value. Clean the cup after testing.
    Read more
    NDJ-1 Rotational Viscometer
    NDJ-8S Rotational Viscometer
    ISO Viscosity Cup
    Tu 4 Viscosity Cup
    DIN Viscosity Cup
    Tu 4 Viscosity Cup
    Range: 1 ~ 100,000mPa
    Range:1 ~ 2 x 1,000,000mPa
    3#: Φ3mm; 7-42cst
    Orifice: Φ4mm
    Orifice: Φ4 mm
    Orifice: Φ4mm
    Rotor: 1#2#3#4#
    Rotor: 1#2#3#4#
    4#: Φ4mm; 34-135cst
    Viscosity range: 112-685cst
    Viscosity range: 96-683cst
    Viscosity range: 112-685cst
    Error: ±5%
    Error: 2%
    5#: Φ5mm; 91-326cst
    Outflow time:≤150S
    Outflow time: 20-110s
    Outflow Time:30-100s
    Voltage: 220V with 110V voltage transformer
    Voltage: 110V
    6#: Φ6mm; 188-684cst
    Volume: 100ml
    Volume: 100ml
    Volume: 100ml
    Reading: Pointer
    Reading: Digital
    8#: Φ8mm; 600-2000cst
    Zahn Cup Application
    Zahn Cup
    can be used to quickly determine the viscosity of printing ink, dyes, coatings, experimental solvents, leather paint, oil, grease, food and other mobile liquids in the printing industry such as paint, varnish, wet enamel, gravure, relief, lithography, flexography, silk plate, etc.
    Zahn Cup
    is often used as a fast viscosity measuring tool in workshops and at the spot.
    Shipping and Handling
    Please allow 5-7 business days for the package to arrive, regardless of buyer location within the US.
    We will provide an online tracking number to you once the item has been shipped.
    It may take a few business days for our automated system to process the tracking number onto eBay. However, this will not affect the shipping times.
    Return Policy
    All our products are brand new and sealed. All items qualify for returns within 30 days of receipt.
    Feedback
    We take our reputation seriously. If you have any questions or concerns, please contact us and we will respond back to your message within 24 hours.