-40%

Brookfield Model KU-3 Krebs Unit Viscometer

$ 2349.6

Availability: 100 in stock
  • Condition: New
  • All returns accepted: ReturnsNotAccepted
  • Country/Region of Manufacture: United States
  • Type: KU-3 KrebS Viscometer
  • MPN: Does Not Apply
  • Model: KU-3
  • Brand: Brookfield

    Description

    Brookfield Krebs Unit Viscometer Model KU-3
    KU-3 Viscometer
    The KU-3 Viscometer displays, Krebs units, gram units and centipoise for paints, coatings and inks.
    Brookfield offers a completely digital calculating Krebs Unit Instrument with all the reliability you'd expect in Brookfield instrumentation...now with relative centipoise display.
    Why the KU-3? This instrument is used widely for making viscosity measurements on paints/coatings in accordance with ASTM D562.
    FEATURES AND BENEFITS
    Continuous sensing and display in Krebs units, grams, and centipoise.
    Magnetic spindle coupling.
    Allows rapid sample measurement to determine required consistency.
    LED Digital Display of: Krebs Units (increased resolution in 0.1 KU increments), Grams (in 1 gm increments) and Centipoise (cP).
    Expanded measurement range (40 to 141 KU; 32 to 1099 g; 27 to 5274 cP).
    Accuracy to ±1% of full scale range.
    Reproducibility to ±0.5% of full scale range.
    Easy to use; no weights; simplifies an established test procedure.
    Compatible with industry specification (ASTM D562).
    Base accommodates standard pint, ½ pint, and quart cans.
    The optional paste spindle is suitable for use with high consistency materials such as roller mill pastes.
    NIST traceable viscosity standards available.
    What’s Included?
    Instrument
    Krebs-type Spindle (KU-1030)
    Adapter for Pint and Half-Pint Can
    Technical Data
    Technical Data
    Range:
    40 to 141 KU; 32 to 1099 gm; 27 to 5,274 cP
    Resolution:
    Within 0.1 KU or 1 gm
    Accuracy:
    Within ±1% of full scale range
    Reproducibility:
    Within ±0.5% of full scale range
    Operating Temperature:
    10°C to 40°C
    Spindle Speed:
    200 rpm ±0.1rpm
    Measuring Containers:
    1 pint, 1/2 pint, 1 quart cans
    Power Line Requirement:
    115 V/60 Hz
    References:
    ASTM D562
    Shipping Weight:
    22 lbs. (10 kg)
    Applications
    Paints & Coatings
    Adhesives
    Inks
    Pastes
    Optional Accessories Please contact:  Scinteck Instruments
    How it Works
    Samples are tested in standard paint industry cans held by a fixture located on the viscometer base. The can is filled to within 3/4" (20mm) of the top. The KU-3 operating lever has two positions:
    Up: Spindle stationary, drive motor off
    Down: Spindle rotating; sample being measured
    The displayed reading can be held by depressing the HOLD switch at any time. With the viscometer in the HOLD configuration, the display may be switched to compare the Krebs unit (KU) reading with the associated gram (gm) reading, and centipoise. Brookfield Oil Viscosity Standards in Krebs units are NIST traceable and are recommended for verifying calibration of the KU-3 Viscometer.
    More Information
    Annual Calibration Service is Recommended
    - We recommend that this instrument be returned on an annual basis. Having this annual maintenance done will ensure the instrument's long life and optimal performance.
    The air-purge option is not available in the Model KU-3.
    Please note:
    The cP reading from the KU-3 will not necessarily agree with cP values
    measured with other instrumentation due to:
    Unique shear rate of the KU-3 paddle spindle.
    Uniqueness of the Krebs unit scale. (The centipoise value should not be used for purposes of calibration.)
    Use only Brookfield KU mineral oils for calibration check.
    The cP readings will only be valid when using the paddle spindle.
    The paste spindle may not be used to determine cP.
    Conversion Between Stormer Viscometer Krebs Units and Viscosity Cup Drain Time
    The three reduced size charts, at left. are only for illustrating this conversion method. Ask for complimentary full size (8-1/2" x 11") Krebs Units Conversion Charts and latest Krebs Stormer literature.
    Three Step Conversion Procedure
    Step 1:
    Knowing the Krebs value, convert this value to Centipoise viscosity. On the attached Krebs Units to Centipoise conversion chart, read vertically from the known Krebs unit to the curve and then horizontally to the left to the Centipoise value. Record this value.
    Step 2:
    Convert the Centipoise value for the test material in question to Centistokes. On the attached Centipoise - Centistoke conversion chart, locate the Centipoise value from Step 1 on the vertical scale.Read horizontally to the right from this value to the Weight Per Gallon or Specific Gravity line, estimating values between lines, applicable to the test material in question. From this intersection read directly downward to the horizontal Centistoke scale and record this value.
    Step 3:
    Determine the drain time in seconds for the viscosity cup in question from the Centistoke value from Step 2. For this conversion, refer to the Gardco Viscosity Cup Equivalent Chart or the conversion chart furnished with each Gardco produced viscosity cup. Only viscosity cups accommodating the highest range of viscosity are satisfactory for this conversion as most Krebs measurements are in the range from 500 to 1400 Centistokes.
    For satisfactory results, do no use a viscosity cup above its recommended top limit. This conversion is accurate only for Newtonian or near Newtonian materials. Viscosity of materials that deviate greatly from these true liquids may not be “seen” the same by the Stormer and viscosity cup methods of measurement.
    Please refer to the appropriate cup conversion chart. If you do not have one please contact us at 1-800-762-2478 or 954-946-9454.
    Related Accessories
    KU-3 Spindles
    The KU-3 Viscometer can be used with two different spindles.
    The "standard" Krebs spindle is ideal for most paint and coatings operation, while the optional Paste spindle is designed for high viscosity materials such as roller mill pastes.
    Krebs Viscometer Oil Fluids
    Krebs Oil Fluids are for use with the Brookfield KU series Viscometers. Like all Brookfield Viscosity Standards, the Krebs Oil Fluids are accurate to ±1%.
    Krebs Oil Fluids are for use with the KU series Viscometers. Like all Brookfield Viscosity Standards, the Krebs Oil Fluids are accurate to ±1% of stated viscosity values. Krebs Oil Fluids are supplied in 1/2 liter (1 pint) containers complete with certificate of calibration.
    Confused about which standards you need? See our
    FAQ section
    .
    FEATURES & BENEFITS
    Accuracy: ±1% of viscosity value
    Appropriate for use at shear rates greater than 500 sec-1
    Recommended for Brookfield KU series Viscometers
    Brookfield oil viscosity standards are hydrocarbon based, either mineral oil or polybutenes.
    Note: Other oil fluids are available - call for details
    Brookfield Viscosity Standards are accurate to ±1% of the stated viscosity and are certified by methods traceable to the United States National Institute of Standards and Technology (NIST). The selection of one or two fluids will normally provide sufficient measurement points to verify calibration of your instrument. All fluids are supplied in 1/2 liter (1 pint) containers complete with a certificate of calibration.
    Don't see what you're looking for? Maybe our
    Special Order Silicone Fluids
    are for you!
    ABOUT REACH COMPLIANCY
    REACH is the European Community Regulation on chemicals and their safe use (EC 1907/2006). It deals with the Registration, Evaluation, Authorisation and Restriction of Chemical substances. The law entered into force on 1 June 2007.
    The aim of REACH is to improve the protection of human health and the environment through the better and earlier identification of the intrinsic properties of chemical substances. At the same time, REACH aims to enhance innovation and competitiveness of the EU chemicals industry.
    Specifications
    -
    SPECIFICATIONS
    Krebs Viscometer Oil Fluids
    Brookfield
    Part #
    Nominal Viscosity cP
    Krebs Units
    Temp
    °C
    KU61
    61
    25°C
    KU73
    73
    25°C
    KU87
    87
    25°C
    Scinteck Instruments LLC