-40%

Brookfield Small Sample Adapter W RTD & Cable

$ 264

Availability: 20 in stock
  • Brand: Brookfield
  • MPN: Small Sample Adapter
  • Condition: May not be complete. See the listing and see what is included.

    Description

    Brookfield Small Sample Adapter W RTD & Cable
    This is a
    Brookfield Small Sample Adapter W RTD & Cable
    .
    What you will get:
    1 Brookfield Small Sample Adapter W RTD & Cable Consisting of:
    Brookfield SC4-46Y Locating Channel Bracket
    Brookfield SC4-53 Insulating Cap
    Brookfield SC4-RPY RTD Temperature Probe and Connector Cable
    Brookfield SC4-45Y Water Jacket Assembly w Cable
    Instructions
    Case
    This is my item R3B10S1 0239.  This could possibly be incomplete.  Please look at the pictures and the accessories that are included and make a decision based on the pictures.
    1 was available at listing time.
    Check out my
    other items
    where I have a lot of other Brookfield Accessories for sale.
    More Information:
    This instruction sheet applies to the Small Sample Adapter with stainless steel chamber (with black water jacket) as well as disposable sample chamber (with gray water jacket) that will be used with either the Standard spindle coupling nut or the EZ-Lock spindle coupling system. Spindles that can be used with the Small Sample Adapter are identified in Tables 2 and 4. 1. Mount the viscometer securely on its laboratory stand per the operating instructions that came with the laboratory stand. 2. Attach the locating channel (alignment bracket) to the viscometer (refer to illustration on pages 2 and 3) by threading the mounting screw into the tapped hole in the Viscometer pivot cup. Do not overtighten. Note the position of the locating pin. 3. Connect a length of 1/4 or 5/16 inch inside-diameter hose from the circulating bath outlet to the lower (inlet) fitting on the water jacket. Connect another length of hose from the upper (outlet) fitting to the bath (inlet) fitting. Hoses should be long enough to allow proper flow to the water jacket without exerting any “side thrust” on the assembly during operation. Minimum temperature is 0°C and maximum temperature is 100°C; over 60°C, use high temperature tubing. For tubing and fluid recommendations, see Table 1.
    Please use the shipping calculator to determine shipping.
    Check out my
    other items
    !
    If you receive your item and it is not to your 100 Percent Satisfaction, please contact us before leaving feedback.
    I strive to make sure every transaction is a positive one!
    IF you have a problem with my item, I would like you to use the "Contact Seller" link in the listing, or call me. Please don't open a case. Cases count against me even if they are resolved.
    I stand behind my items and will work out any problems that you may have with an item.
    So please contact me if you have a problem with an item I have sold you and don't use the eBay Case as a means of communication.
    International Buyers, Please Note: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying. These charges are normally collected by the delivering freight (shipping) company or when you pick the item up do not confuse them for additional shipping charges. We do not mark merchandise values below value or mark items as "gifts". US and International government regulations prohibit such behavior.
    Powered by SixBit's eCommerce Solution